dc.identifier.citationAçıkgöz, Ş. (2014). Su örneklerinde organik reaktifler ve UV-VIS spektrofotometre kullanarak metal tayini için bir dağıtıcı sıvı-sıvı mikroekstraksiyon (DLLME) yöntemi geliştirme. Yüksek Lisans Tezi. Yozgat Bozok Üniversitesi Fen Bilimleri Enstitüsü, Yozgat.en_US
dc.identifier.urihttp://dspace.bozok.edu.tr/xmlui/handle/11460/384
dc.description.abstractBu çalışmada, yeni, hassas, basit, etkili ve valide edilmiş bir metot spektrometrik analiz için Dispersif Sıvı-Sıvı Mikroekstraksiyon (DLLME) tekniği kullanarak, farklı su örneklerindeki Ni(II), Cu(II) ve Zn(II)'nin tayini için geliştirildi. Ekstraksiyon işlemi Ni(II), Cu(II) ve Zn(II)'nin yeni bir ligand olan 4-benzoil-N-[(dietilamino)karbonotiyolil]-1,5-difenil-1H-pirazol-3-karboksimat ile kompleks oluşturması, sonra DLLME tekniği kullanarak kompleksin ekstraksiyonuna dayanır. Ekstraksiyon ve dispersif çözücüsünün hacmi ve tipi, ekstraksiyon periyodu gibi bazı önemli parametreler detaylıca araştırıldı ve optimize edildi. Optimize edilen koşullarda Ni(II), Cu(II) ve Zn(II) için kalibrasyon grafikleri lineer aralıkları sırasıyla 0.033-0.666, 0.132-4.000, 0.033-5.000 µg mL-1, gözlenebilme sınırları sırasıyla 0.012, 0.027, 0.159 µg mL-1 dir. Ni, Cu ve Zn sırasıyla 0.066, 0.132, 3.330 μg mL-1 seviyelerinde beş tekrar ölçümleri için bağıl standart sapmaları % 7.1, % 9.4, % 1.9 olarak hesaplandı. Geliştirilen metot su örneklerine uygulandı.en_US
dc.description.abstractIn the present study, new, sensitive, simple, efficient and validated method was developed for the determination of Ni(II), Cu(II) and Zn(II) in different water samples using dispersive liquid-liquid microextraction (DLLME) technique followed by spectrophotometric analysis. The procedure is based on the complexation of Ni(II), Cu(II) and Zn(II) with a new complex of 4-benzoyl-N-[(diethylamino)carbonothioyl]-1,5-diphenyl-1H-pyrazole-3-carboxamide, then the extraction of the complex using DLLME technique. Some important parameters such as the type and volume of extraction and dispersive solvents as well as the extraction period were investigated and optimized in detail. Under the optimum conditions, the calibration graphs for Ni(II), Cu(II) and Zn(II) were linear over the ranges of 0.033-0.666, 0.132-4.000, 0.033-5.000 µg mL-1 with the limits of detection of 0.012, 0.027, 0.159 µg mL-1 respectively. Relative standard deviations for five replicate measurements of Ni(II), Cu(II) and Zn(II) at 0.066, 0.132, 3.330 μg mL-1 was calculated as 7.1 %, 9.4 %, 1.9 % respectively. The method was applied to water samples.en_US
dc.language.isotr_TRen_US
dc.publisherFen Bilimleri Enstitüsüen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectZenginleştirmeen_US
dc.subjectmikroekstraksiyonen_US
dc.subjectUV-VIS spektrofotometreen_US
dc.subjectsu örneklerien_US
dc.subjectmetalen_US
dc.subjectPreconcentrationen_US
dc.subjectmicroextractionen_US
dc.subjectUV-VIS Spectrophotometryen_US
dc.subjectwater samplesen_US
dc.subjectmetalsen_US
dc.titleSu örneklerinde organik reaktifler ve UV-VIS spektrofotometre kullanarak metal tayini için bir dağıtıcı sıvı-sıvı mikroekstraksiyon (DLLME) yöntemi geliştirmeen_US
dc.title.alternativeDevelopment of a dispersive liquid-liquid microextraction (DLLME) method for the determination of metal in water samples using organic reagents and UV-VIS spectrophotometryen_US